Orion Oil-Less Rotary Vane Combination Pump CBF Series

Request Quote

For Pricing & Availability Visit Compressor Now Equipment

View Pricing or Purchase

SKU: N/A Categories: ,
Clear

Description

CBF Combination Dry Pump

Proven Design, Low Operating Noise, Long Life. Environmentally Friendly Pump for the Next Generation

CBF1515 / CBF2525 / CBF4040

Continuous Degree of Vacuum: Recommended
60 kPa or lower (V type)
Continuous Degree of Exhaust Pressure
Recommended: 60 kPa or lower (B type)
Continuous Pressure: Recommended total degree of vacuum and exhaust pressure
60 kPa or lower (VB type)
Flow Rate
280 to 685 L/min (60 Hz)
  • Proven Design and Environmentally Friendly
    CE Marking and RoHS Directive Compliant
  • Low Operating Noise
    Noise-reducing design reduces noise by 3 dB (compared with our earlier models.)
  • Long Lifespan
    New blade material yields an increased lifespan of 30% (compared with our earlier models).

Specifications

Model CBF1515- VB-01B VB-04B ※3 VBVB-01B VBVB-04B ※3
Designed Exhaust Flow Rate (50/60 Hz) ※1 L/min Pump 1 (V): 235/280
Pump 2 (V):235/280
Pump 1 (V,B): 235/280
Pump 2 (V,B):235/280
Continuous Degree of Vacuum (V) ※2 kPa (min.) 60
Continuous Exhaust Pressure (B) ※2 kPa (min.) 60
Continuous Exhaust Pressure (VB) kPa Recommended ※5, Maximum ※6
Piping Connection Size Rc 3/4
Voltage (50/60 Hz) V Three-phase 200/
Three-phase 200, 220, 230
Three-phase 380, 400, 415/
Three-phase 400, 440, 460
Three-phase 200/
Three-phase 200, 220, 230
Three-phase 380, 400、415/
Three-phase 400, 440, 460
Standard Motor Current Rating (50/60 Hz) A 3.8/
3.4, 3.4, 3.4
2.0, 1.9, 1.9/
1.7, 1.7, 1.7
3.8/
3.4, 3.4, 3.4
2.0, 1.9, 1.9/
1.7, 1.7, 1.7
Operating Noise Level (50/60 Hz) ※4 dB 62/63 65/66
Built-In Motor kW 0.75
Mass kg 37
Model CBF1515- VV-01B BB-01B
Designed Exhaust Flow Rate (50/60 Hz) ※1 L/min Pump 1 (V): 235/280
Pump 2 (V):235/280
Pump 1 (B): 235/280
Pump 2 (B):235/280
Continuous Degree of Vacuum (V) ※2 kPa (min.) 60
Continuous Exhaust Pressure (B) ※2 kPa (min.) 60
Continuous Exhaust Pressure (VB) kPa
Piping Connection Size Rc 3/4
Voltage (50/60 Hz) V Three-phase 200/ Three-phase 200, 220, 230
Standard Motor Current Rating (50/60 Hz) A 3.8/3.4, 3.4, 3.4
Operating Noise Level (50/60 Hz) ※4 dB 61/62 65/66
Built-In Motor kW 0.75
Mass kg 37
Model CBF2525- VB-01B VB-04B ※3 VBVB-01B VBVB-04B ※3
Designed Exhaust Flow Rate (50/60 Hz) ※1 L/min Pump 1 (V): 405/480
Pump 2 (V):405/480
Pump 1 (V,B): 405/480
Pump 2 (V,B):405/480
Continuous Degree of Vacuum (V) ※2 kPa (min.) 60
Continuous Exhaust Pressure (B) ※2 kPa (min.) 60
Continuous Exhaust Pressure (VB) kPa Recommended ※5, Maximum ※6
Piping Connection Size Rc 3/4
Voltage (50/60 Hz) V Three-phase 200/
Three-phase 200, 220, 230
Three-phase 380, 400, 415/
Three-phase 400, 440, 460
Three-phase 200/
Three-phase 200, 220, 230
Three-phase 380, 400、415/
Three-phase 400, 440, 460
Standard Motor Current Rating (50/60 Hz) A 6.8/
6.4, 6.0, 6.0
3.5, 3.4, 3.4/
3.2, 3.0, 3.0
6.8/
6.4, 6.0, 6.0
3.5, 3.4, 3.4/
3.2, 3.0, 3.0
Operating Noise Level (50/60 Hz) ※4 dB 64/67 67/70
Built-In Motor kW 1.5
Mass kg 52
Model CBF2525- VV-01B BB-01B
Designed Exhaust Flow Rate (50/60 Hz) ※1 L/min Pump 1 (V): 405/480
Pump 2 (V):405/480
Pump 1 (B): 405/480
Pump 2 (B):405/480
Continuous Degree of Vacuum (V) ※2 kPa (min.) 60
Continuous Exhaust Pressure (B) ※2 kPa (min.) 60
Continuous Exhaust Pressure (VB) kPa
Piping Connection Size Rc 3/4
Voltage (50/60 Hz) V Three-phase 200/ Three-phase 200, 220, 230
Standard Motor Current Rating (50/60 Hz) A 6.8/6.4, 6.0, 6.0
Operating Noise Level (50/60 Hz) ※4 dB 63/66 67/70
Built-In Motor kW 1.5
Mass kg 52
Model CBF4040- VB-01B VB-04B ※3 VBVB-01B VBVB-04B ※3
Designed Exhaust Flow Rate (50/60 Hz) ※1 L/min Pump 1 (V): 575/685
Pump 2 (V):575/685
Pump 1(V,B): 575/685
Pump 2 (V,B):575/685
Continuous Degree of Vacuum (V) ※2 kPa (min.) 60
Continuous Exhaust Pressure (B) ※2 kPa (min.) 60
Continuous Exhaust Pressure (VB) kPa Recommended ※5, Maximum ※6
Piping Connection Size Rc 3/4
Voltage (50/60 Hz) V Three-phase 200/
Three-phase 200, 220, 230
Three-phase 380, 400, 415/
Three-phase 400, 440, 460
Three-phase 200/
Three-phase 200, 220, 230
Three-phase 380, 400、415/
Three-phase 400, 440, 460
Standard Motor Current Rating (50/60 Hz) A 10.6/
9.4, 9.2, 9.2
5.3, 5.3, 5.4/
4.7, 4.6, 4.6
10.6/
9.4、9.2、9.2
5.3, 5.3, 5.4/
4.7, 4.6, 4.6
Operating Noise Level (50/60 Hz) ※4 dB 68/70 69/71
Built-In Motor kW 2.2
Mass kg 67
Model CBF4040- VV-01B BB-01B
Designed Exhaust Flow Rate (50/60 Hz) ※1 L/min Pump 1 (V): 575/685
Pump 2 (V):575/685
Pump 1 (B): 575/685
Pump 2 (B):575/685
Continuous Degree of Vacuum (V) ※2 kPa (min.) 60
Continuous Exhaust Pressure (B) ※2 kPa (min.) 60
Continuous Exhaust Pressure (VB) kPa
Piping Connection Size Rc 3/4
Voltage (50/60 Hz) V Three-phase 200/ Three-phase 200, 220, 230
Standard Motor Current Rating (50/60 Hz) A 10.6/9.4, 9.2, 9.2
Operating Noise Level (50/60 Hz) ※4 dB 67/69 71/73
Built-In Motor kW 2.2
Mass kg 67
  1. Designed Pumping Capacity: Theoretical value based on volume. Refer to performance data for actual flow rate.
  2. Operable range of vacuum and exhaust pressure.
  3. “04” models are built-to-order items.
  4. Actual operating noise measured on a new pump with the ORION recommended motor running under standard vacuum/pressure conditions. Operating noise level is from a position of 1 m in front of the product and at a height of 1 m.
  5. Recommended range: Combined total of degree of vacuum and exhaust pressure is 60 or lower.
  6. Maximum values: Total of the following degree-of-vacuum / exhaust-pressure combinations: 55/20, 55/30, 40/40, 35/50.Maximum values: The maximum continuous degree of vacuum of the dry pump and the upper limit of exhaust pressure. Do not operate the pump beyond these maximum values. Doing so can reduce the lifespan of the pump and may result in breakdown or an accident.
  • There may be a possibility of pump damage in applications involving extremely low humidity-controlled environments. Please consult your dealer if this is a concern.
  • The allowable intermittent power supply voltage fluctuation range is ±10%, and the allowable sustained supply voltage fluctuation range is ±5% of the specified voltage.
  • When using a motor other than the ORION standard motor, follow the electrical guidelines printed on the nameplate of the motor used.
  • Please install an overload protection device (such as a thermal relay).

Additional information

Flow (CFM)

10-20, 17-34, 24-48, 67-100

Manufacturer

Manufacturer Type

OEM

Horse Power

1, 2, 3